Ceramic Master Е1000 en v3 12
When programming the temperature conditions for
parameters ENTRY TEMP, DRY2 TEMP, FIRE1 TEMP, FIRE2
TEMP and COOL1 TEMP the program temperature cannot
be lower than this of the previous parameter and at the
same time higher than this of the next parameter.
Please consider that the data which you initiated in the
skipped temperature-concerned parameters (by
manipulating with button SKIP) exert influence on the
programming of the adjacent temperature parameters.
The difference between the values of the parameters
ENTRY TEMP and DRY2 TEMP can’t be lower than 20°C!
For instance supposing that the defined value of the
parameter ENTRY TEMP is 500°C, then the value of the
parameter DRY2 TEMP can be 520°C or more.
There is a possibility for fast changing of parameters
which have TEMPERATURE and TIME dimensions. When
you push the button and rotate the MFRK the value
will change by 100 points, and by pushing and rotate
the MFRK the value will change by 10 points.