SID SPN FMI
Warning
Light
Programming
Error Code
Message
Displayed
Description/Action
253 630 2 ABS WL B15
Unable to write checksum to ECU:
Block [block information] (Error: B15).
Please exit this window, cycle power
and try again. If the problem persists,
please contact WABCO North America
Customer Care at 855-228-3203.
This failure may occur if communication with the ECU is interrupted during the
configuration session. Close the TOOLBOX™ Software, reopen it, and restart the
aftermarket programming application. If the problem persists, repeat with key on only
(Engine Off).
This failure will also occur when one or more of the following are not connected: Power,
Ground, J1939 CAN High, or J1939 CAN Low. Check for continuity.
253 630 2 ABS WL B16
Communication Error (Error: B16).
Please exit this window, cycle power,
and try again. If the problem persists,
please contact WABCO North America
Customer Care at 855-228-3203.
This failure may occur if communication with the ECU is interrupted during the
configuration session. Close the TOOLBOX™ Software, reopen it, and restart the
aftermarket programming application. If the problem persists, repeat with key on only
(Engine Off).
This failure will also occur when one or more of the following are not connected: Power,
Ground, J1939 CAN High, or J1939 CAN Low. Check for continuity.
253 630 2 ABS WL B17
Parameter Incompatibility (Error: B17).
Please contact WABCO North America
Customer Care at 855-228-3203.
Close the TOOLBOX™ Software, reopen it and restart the aftermarket programming
application. If the problem persists, repeat with key on only (Engine Off).
253 630 2 ABS WL B18
Unable to read memory address before
setting parameter (Error: B18). Please
exit this window, cycle power and try
again. If the problem persists, please
contact WABCO North America
Customer Care at 855-228-3203.
This failure may occur if communication with the ECU is interrupted during the
configuration session. Close the TOOLBOX™ Software, reopen it and restart the
aftermarket programming application. If the problem persists, repeat with key on only
(Engine Off).
This failure will also occur when one or more of the following are not connected: Power,
Ground, J1939 CAN High, or J1939 CAN Low. Check for continuity.
253 630 2 ABS WL B19
VCP program error: ByteToChange
for [parameter information] neither
0 nor 1 (Error: B19). Please exit this
window, cycle power and try again. If
the problem persists, please contact
WABCO North America Customer Care
at 855-228-3203.
This failure may occur if communication with the ECU is interrupted during the
configuration session. Close the TOOLBOX™ Software, reopen it and restart the
aftermarket programming application. If the problem persists, repeat with key on only
(Engine Off).
This failure will also occur when one or more of the following are not connected: Power,
Ground, J1939 CAN High, or J1939 CAN Low. Check for continuity.
253 630 2 ABS WL B20
Unable to write parameter: [parameter
information] (Error: B20). Please exit
this window, cycle power, and try again.
If the problem persists, please contact
WABCO North America Customer Care
at 855-228-3203.
This failure may occur if communication with the ECU is interrupted during the
configuration session. Close the TOOLBOX™ Software, reopen it and restart the
aftermarket programming application. If the problem persists, repeat with key on only
(Engine Off).
This failure will also occur when one or more of the following are not connected: Power,
Ground, J1939 CAN High, or J1939 CAN Low. Check for continuity.
253 630 2 ABS WL B21
Error while trying to set parameters
(Error: B21). Please exit this window,
cycle power and try again. If the
problem persists, please contact
WABCO North America Customer Care
at 855-228-3203.
This failure may occur if communication with the ECU is interrupted during the
configuration session. Close the TOOLBOX™ Software, reopen it and restart the
aftermarket programming application. If the problem persists, repeat with key on only
(Engine Off).
This failure will also occur when one or more of the following are not connected: Power,
Ground, J1939 CAN High, or J1939 CAN Low. Check for continuity.
4012094a