10 Maintenance
31 100_0302_mt_0001.fm
3. Use a clean funnel to replenish fuel.
See chapter Technical data for the fuel specification.
See chapter Technical data for the fuel mixing table.
4. Position the fuel cap and tighten it.
10.4.3 Checking/cleaning air cleaner
Performing preparations
1. Switch off the engine.
2. Lean the machine upright against a solid object and secure it to prevent it from toppling over.
Wacker Neuson recommends to hang the machine on the truck.
3. Let machine cool off.
Removing the air cleaner cartridge
1. Remove any dirt around the air cleaner cap.
2. Unscrew and remove all nuts of the air cleaner cap.
3. Remove the air cleaner cap.
4. Remove air cleaner cartridge.
Checking/cleaning air cleaner cartridge
Tap out air cleaner cartridge and blow out from inside to outside with compressed air.
If the dust can no longer be removed, change the air cleaner cartridge.
Installing air cleaner cartridge
1. Insert air cleaner cartridge.
2. Replace air cleaner cap.
3. Tighten all nuts of the air cleaner cap securely.
NOTICE
Slowly unscrew the fuel cap so that any overpressure can slowly escape.
NOTICE
When tapping, make sure that the air cleaner cartridge is not damaged.
NOTICE
Operating the engine without air cleaner can cause rapid engine wear.
Do not run the engine without an air cleaner or air cleaner cap.

Table of Contents