T00883GB
14
OPERATION
Switching off
1. Push down press button switch from vibration position to stop position. The control lamp will extinguish.
2. Move throttle lever (16) all the way to the stop position.
3. Turn the ignition key to the stop position and pull off once engine has stopped turning. The control lamp will
turn off.
Compaction without extension plates
If the vibration plates is used without extension plates, screw set of protective screws (8 pes) No. 0067520 into
the threaded boreholes situated in the lower mass, in order to avoid threads from being damaged.
Starting with external battery etc.
Observe the following connection sequence when using an external battery to start the engine:
1. Connect one end of jumper cable to positive terminal of auxiliary battery.
2. Connect the other end of jumper cable to positive terminal of the defective vibro plate battery.
3. Now connect jumper cable clamp to negative terminal of the auxiliary battery.
4. Connect other end of jumper cable to the upper mass of the vibratory plate, e.g. to the motor fixing screws.
The connection point should be as far away as possible from the battery of the vibratory plate.
Disconnect jumper cable in reverse order.
☛ATTENTION! Only 12 V batteries may be used. The use of e.g. a 24 V truck battery will lead to an
explosion of the vibro plate battery!
Additional notes on starting at very low temperatures!
☛ATTENTION! Never use starting sprays or similar - they are forbidden because they are dangerous.