T01044GB 24
6.7 External starting
Observe the following connection sequence when using an external battery
to start the engine:
Only 12 V batteries may be used. The use of e.g. a 24 V truck battery
will lead to an explosion of the vibro plate battery!
Only use insulated jumper cables!
1. Stop engine.
2. In the first place connect the red battery jumper cable to the positive
pole of the dead battery and then connect the other end to the
positive pole of the charged battery.
3. In the second place connect the black cable to the negative pole of
the charged battery and only then connect the other end to the
negative pole of the dead battery.
4. Start the engine (max. 15 seconds) and then let the engine run.
5. Proceed in inverse order to disconnect the jumper cable.
6.8 Additional notes on starting at very low temperatures!
Never use starting sprays or similar - they are forbidden because they
are dangerous.
6.9 When there is danger of frost
After cleaning with water or a steam jet, run the machine to warm it
before shutting it down.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU 7060SC and is the answer not in the manual?

Wacker Neuson DPU 7060SC Specifications

General IconGeneral
ModelDPU 7060SC
ManufacturerWacker Neuson
CategoryPower Tool
Centrifugal Force70 kN
TypeReversible Plate Compactor

Related product manuals