Faults
T01052GB 31
Pressing the ”0” button (e) does not shut down the machine LED ring
(b) stays illuminated
8.2 Disturbance on sender
The sender LED (m) does not start blinking when the rocker switch (h)
is in the ”I” position
LED ring (b) illuminates but does not blink, although the machine is
switched on and an activated sender is pointed at the receiver eye
LED ring (b) blinks but the machine does not react to the starter button
(i)
Cause Remedy
Button defective.
Replace the button with an original
replacement part.
Button has no electrical contact.
Check connection and repair.
Cause Remedy
Sender battery is discharged.
Replace battery with charged battery.
Operate the machine with the spiral
cable attached, automatically cha ging
the battery.
Sender defective.
Contact Wacker service dept.
Cause Remedy
Sender and receiver not using the same
channel.
Open sender, set proper channel.
Cause Remedy
Starter damaged or connection defetive.
Contact Wacker service dept.
The vibratory plate’s on-board battery is
largely discharged.
Charge the battery and check the
functionality of the charge regulator
if necessary.