50 wc_tx001667gb.fm
4.17 Monitoring the Operating Parameters
Background
Monitor the machine while it is operating to ensure safe and efficient operation.
Parameters
Monitor the following parameters every 8–24 hours.
Parameter Notes
Fuel level Add fuel as needed.
HTF level Add HTF as needed.
HTF operating pressure Operating pressure: 90–110 psi.
If operating pressure is higher than 110 psi, check for
kinked hoses.
If operating pressure is less that 90 psi, check HTF level.
HTF return temperature The HTF return temperature tells you how much heat is
being transferred. It can also tell you when a thawing
process is complete, as very little heat will be transferred
at that point. Consult Wacker Neuson Product Support for
detailed information.
Strobe light Flashing strobe signifies that all systems are OK.