E 2200, E 3000ES Accessories
wc_tx001668gb.fm 73
Electrical
connections
Make the following electrical connections.
Connect the power cord from the DPP (e) to the auxiliary receptacle labeled
“PUMP PACK” (b).
Operating
1. Start the parent machine. Turn on the buner and the pumps.
2. Start the pumps of the DPP, one at a time (c).
3. Monitor the HTF flows, pressures, and temperature as the machine operates.
b
e
wc_gr008081
c