GP Repair Maintenance
wc_tx000546gb.fm 39
4.3 Engine Oil
See Graphic: wc_gr000022
4.3.1 Drain the oil while the engine is still warm.
4.3.2 Remove the oil filler plug (a) and the drain plug (b) to drain the oil.
Note: In the interests of environmental protection, place a plastic sheet
and a container under the machine to collect any liquid that drains off.
Dispose of this liquid in accordance with environmental protection
legislation.
4.3.3 Install the drain plug.
4.3.4 Fill the engine crankcase with the recommended oil up to the level of
the plug opening (c). See Technical Data for oil quantity and type.
4.3.5 Install the oil filler plug.