51
EPG-SPRINT.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
Fault numbers Faults Cause Rectifi cation
E21-E25 Exception error. ● Hardware defect has
occurred.
● If problem persists,
contact Wagner Service
Team.
E31 Gun switch
monitoring in
automatic mode.
● The gun switch line has
been interrupted.
● Gun unplugged during
operation.
● Check gun cable.
● Check gun.
E41 No fl ow of atomizing
air.
No air is fl owing out of the
control unit.
Causes:
● Hose kinked / blocked.
● Injector is not connected.
● Compressed air switched
off.
Gun unplugged during
operation.
Check:
● The hose laying.
● The air supply to the
control unit.
● Input pressure >6bar.
● Connect injector.
● Open compressed air.
E42 No fl ow of dosage air. No air is fl owing out of the
control unit.
Causes:
● Hose kinked / blocked.
● Injector is not connected.
● Compressed air switched
off.
Gun unplugged during
operation.
Check:
● The hose laying.
● The air supply to the
control unit.
● Input pressure >6bar.
● Connect injector.
● Open compressed air.
E43 No fl ow of feed air. No air is fl owing out of the
control unit.
Causes:
● Hose kinked / blocked.
● Injector is not connected.
● Compressed air switched
off.
Gun unplugged during
operation.
Check:
● The hose laying.
● The air supply to the
control unit.
● Input pressure >6bar.
● Connect injector.
● Open compressed air.