84
GA 5000EAC
OPERATING MANUAL
VERSION 09/2016 ORDER NUMBER DOC2360922
Connect high-pressure hose to the spray gun.
Test the seal of the spray gun with suitable medium (e.g., ushing agent or Marcol 52) and
a maximum pressure of 25 MPa; 250 bar; 3626 psi. Increase the pressure gradually while
doing so.
Observe the following gun components:
Product connection, nozzle body, product valve (no post-spraying).
11.2 AIR TEST
11.3 PRODUCT PRESSURE TEST
Exploding gas / air mixture!
Danger to life from ying parts and burns.
Never spray into a closed tank.
Ground the tank.
DANGER
11.4 TEST OF SPRAY PATTERN
Check spray pattern in accordance with Chapter 7.3.1
GA 5000EAC
Switch o the atomizing and shaping air, switch on control air.
1. 0.4MPa; 4bar; 58psi: The air valve must switch on correctly.
2. 0.8MPa; 8bar; 116psi: Test for air seal.
3. Switch o control air: The air valve must switch o correctly.