EDITION 01 /2014 PART NO. ZZB022ENG
Description Units T092.00BI T092.00AI
Max allowed  uid temperature °C
F
60°
140
60°
140
Max inlet pressure MPa
bar
psi
30
300
4351
30
300
4351
Adjustment range MPa
bar
psi
3 ÷ 12
30 ÷ 120
435 ÷ 1740
1 ÷ 6
10 ÷ 60
145 ÷ 870
Product inlet connection
(Female)
Inch G 1/4” G 1/4”
Product outlet connection
(Female)
Inch G 1/4” G 1/4”
Manometer connection
(Female)
Inch G 1/4” G 1/4”
Weight Kg
lb
3.20
7.05
3.20
7.05
Description Units T092.00PNI
Max allowed  uid temperature °C
F
60°
140
Max inlet pressure MPa
bar
psi
30
300
4351
Guiding air inlet max. pressure MPa
bar
psi
0.6
6
87
Adjustment range MPa
bar
psi
2 ÷ 12
20 ÷ 120
290 ÷ 1740
Product inlet connection
(Female)
Inch G 1/4”
Product outlet connection
(Female)
Inch G 1/4”
Manometer connection
(Female)
Inch G 1/4”
Air inlet connection
(Female)
Inch G 1/4”
Weight Kg
lb
4.43
9.77