Sound Parameters – Control Delay
133 Waldorf Q User’s Manual
• MAX Returns the maximum value of either Source #1 or Source #2. If Source #1 is
greater than Source #2, the value of Source #1 is returned and vice versa.
Constant -64…+63
Defines a value for modifier functions that require a constant parameter. See the Operation
parameter described above for further details.
Control Delay
This function offers a delay of a user-selected modulation source during a certain time period. This
parameter can be found in the Modulation Matrix after the Modifiers. Additionally the Control Delay
can be used as Standard Modulation Source (M1S…M8S).
Ctr.Delay| Source
000 | off
Ctr.Delay 0...127
Determines the amount of time delaying the selected modulation signal after a note is triggered.
Previously, values would be reset to their default value. With this update, parameter changes are now
audible.
Please note that the Control Delay must be set as the Modulation Source in the Modulation
Matrix for the Modulation Destination to be affected.
Source see Table “Standard Modulation Sources” on page 60
Selects the Modulation Source (and correspondingly its signal) which will be delayed.