CUBE Manual Page 32 - Revision: 5-24-2017
10.
With a Phillips Head Screwdriver, remove one screw
from the UV Lamp Cover Plate.
Remove UV Lamp Cover Plate.
11.
Disconnect the UV Lamp Connector by holding it and
pressing in the clip. Pull the connector towards rear
of the CUBE as shown.
12.
Firmly pull up the UV Lamp while only holding the
lamp by the white end caps.
NOTE: Do not pull the UV lamp out at an angle, as it
may break or damage the internal parts of the CUBE.