WL2FLT Manual Page 13 Revision 10-26-2021
SERVICE REQUIREMENTS
WARNING! Read and understand the contents of this manual before attempting to service
WL2FLT Water Treatment System. Failure to follow the instructions in this manual could
result in death, serious personal injury, or severe property damage. Only trained and
qualified technicians should attempt to install, maintain, or service Waterlogic Equipment.
1. Visually inspect all electrical and water connections for signs of wear or damage.
DANGER! HIGH VOLTAGE ELECTRICAL HAZARD. Unplug before inspection and service.
2. Waterlogic recommends changing the UV Lamp every 12 months.
WARNING! UV-C EMITTER (UV LAMP). This appliance contains a UV-C emitter (UV Lamp).
UV-C radiation may, even in little doses, cause harm to the eyes and skin. Unintended use or
damage to the housing may result in the escape of dangerous UV-C radiation. Never operate
the UV-C emitter if damaged or removed from enclosure. Do not touch or look directly into the
faucet.
CAUTION! UV LAMPS ARE HAZARDOUS. Lamps are considered Hazardous Waste and must
be disposed of accordingly. Refer to Product MSDS sheet for details.
3. Clean the Quartz Spiral that surrounds the UV Lamp with a non-abrasive cloth, descaling solution,
or ultrasonic bath if needed when changing UV Lamps.
CAUTION! UV SYSTEM IS FRAGILE. Never handle the UV lamp or Quartz Spiral with bare
hands. UV Lamp and quartz spiral must be free of oils and contaminants to ensure proper
operation. Use a soft non-abrasive cloth to clean.
4. Sanitize the Cold Tank per instructions in the pre-installation procedures.
5. Clean and sanitize external surfaces of the unit. Use soap and water or chemicals that are
compatible with ABS plastic and will not damage or degrade the product surfaces.
6. Remove and clean the Faucet. Replace as needed.
WARNING! SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS. Use of proper personal
protective equipment such as rubber gloves and eye protection is required.