WL2FLT Manual Page 56 Revision 10-26-2021
17. Water Streams at an Angle
Solution
Rotate the Bung (Blue Silicone) and the JG fittings a few degrees.
Water Feed Pressure
Verify the Incoming Feed with a Pressure Regulator. Should be 40-
60 psi (275-414 kPa) Use Pressure Regulator
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.
Outgoing Flow Rate
Verify the outgoing Flow Rate. Should be 1.6 Liters per minute (0.42
gallons per minute) - Firewall™ Purification.
Dispense water for one minute should measure 1.6 Liters (0.42
gallons) per minute
Change Flow Restrictor if needed.