Watlow EZ-ZONE
®
PM Integrated Controller 65 Chapter 6 Setup Page
Setup Page
Dis-
play
Parameter name
Description
Range Default
Parameter
Appears
in Menu
When
Modbus Rela-
tive
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Data
Type
&
Read/
Write
[`leu]
[ LEv]
Digital Input (5 to 6)
Level
Select which action
will be interpreted as
a true state.
[high] High (37)
[LoW] Low (53)
High Direction
is set to
input
Instance 1
Map 1 Map 2
1320 1560
Offset to next
instance (Map
1 & Map 2)
equals +20
0x6E (110)
1 to 2
1
137 uint
RW
[`leu]
[ LEv]
Digital Input (7 to 12)
Level
Select which action
will be interpreted as
a true state.
[high] High (37)
[LoW] Low (53)
High Direction
is set to
input
Instance 1
Map 1 Map 2
- - - - 1640
Offset to next
instance Map 2
equals +20
0x6E (110)
5 to 12
1
137 uint
RW
[``Fn]
[ Fn]
Digital Input (5 to 12)
Action Function
Select the function
that will be trig-
gered by a true state
for Digital Inputs 5
through 12.
[none] None (61)
[P;StS] Profile Start/Stop,
level triggered (208)
[ProF] Profile Start Number,
edge triggered (196)
[P;hoL] Profile Hold/Resume,
level triggered (207)
[P;diS] Profile Disable, level
triggered (206)
[`t;da] TRU-TUNE+
®
Dis-
able, level triggered (219)
[`oFF] Control Outputs Off,
level triggered (90)
[MAn] Manual/Auto Mode,
level triggered (54)
[tUnE] Tune, edge triggered
(98)
[idLE] Idle Set Point Enable,
level triggered (107)
[`F;AL] Force Alarm, level
triggered (218)
[`AoF] Alarm Outputs &
Control Loop Off, level trig-
gered (220)
[`SiL] Silence Alarms, edge
triggered (108)
[ALM] Alarm Reset, edge
triggered (6)
[P;LoC] Lock Keypad, level
triggered (217)
[usr;r] Restore User Set-
tings, edge triggered (227)
[LMr] Limit Reset, edge
triggered (82)
None Direction is
set to Out-
put.
Instance 1
Map 1 Map 2
1324 1564
Offset to next
instance (Map
1 & Map 2)
equals +20
0x6E (110)
5 to 12
3
138 uint
RWES
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with other
interfaces.
* Available with PM4, PM8 and PM9 models only
R: Read
W: Write
E:
EE-
PROM
S:
User
Set