PM Integrated Controller 72 Chapter 6 Setup Page
Setup Page
Dis-
play
Parameter name
Description
Range Default
Parameter
Appears
in Menu
When
Modbus Rela-
tive
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Data
Type
&
Read/
Write
[``Fi]
[ Fi]
Output (1 or 3 pro-
cess)
Function Instance
Set the instance of
the function selected
above.
1 to 4 1 Always if
digit 6 or
10 of part
number is
an "F".
Instance 1
Map 1 Map 2
726 846
Instance 3
Map 1 Map 2
806 926
0x76 (118)
1 or 3
4
98 uint
RWES
[`S;Lo]
[ S.Lo]
Output (1 or 3 pro-
cess)
Scale Low
Set the minimum
value of the output
range.
-100.0 to 100.0 0.00 Always if
digit 6 or
10 of part
number is
an "F".
Instance 1
Map 1 Map 2
736 856
Instance 3
Map 1 Map 2
816 936
0x76 (118)
1 or 3
9
99 float
RWES
[`S;hi]
[ S.hi]
Output (1 or 3 pro-
cess)
Scale High
Set the maximum
value of the output
range.
-100.0 to 100.0 10.00 Always if
digit 6 or
10 of part
number is
an "F".
Instance 1
Map 1 Map 2
738 858
Instance 3
Map 1 Map 2
818 938
0x76 (118)
1 or 3
0xA (10)
100 float
RWES
[`r;Lo]
[ r.Lo]
Output (1 or 3 pro-
cess)
Range Low
Set the minimum
value of the retrans-
mit value range
in process units.
When the retrans-
mit source is at this
value, the retransmit
output will be at its
Scale Low value.
-1,999.000to9,999.000°For
units
-1,128.000to5,537.000°C
0.0°For
units
-18°C
Always if
digit 6 or
10 of part
number is
an "F".
Instance 1
Map 1 Map 2
740 860
Instance 3
Map 1 Map 2
820 940
0x76 (118)
1 or 3
0xB (11)
101 float
RWES
[`r;hi]
[ r.hi]
Output (1 or 3 pro-
cess)
Range High
Set the maximum
value of the retrans-
mit value range
in process units.
When the retrans-
mit source is at this
value, the retransmit
output will be at its
Scale High value.
-1,999.000to9,999.000°For
units
-1,128.000to5,537.000°C
9,999.0°F
or units
5,537.0°C
Always if
digit 6 or
10 of part
number is
an "F".
Instance 1
Map 1 Map 2
742 862
Instance 2
Map 1 Map 2
822 942
0x76 (118)
1 or 3
0xC (12)
102 float
RWES
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with other
interfaces.
* Available with PM4, PM8 and PM9 models only
R: Read
W: Write
E:
EE-
PROM
S:
User
Set

Table of Contents