Check this option if you want the programmer to check device ID before erasing, programming etc. If the
device is not equipped, the device will cause a ‘Warning! Device Code Error!’ error before each operation.
Note that even if device ID is bad sometimes, the device will still be programmed. You can cancel it.
10.6.3 Mass Production Mode
In this mode, you just put a device into socket. The system will automatically detect and program the device;
you don’t need to press any key.
Before entering Mass Production Mode, you should select the device you want to program and set the Edit
Auto first. For instance,setting Blank Check, Program etc.
After click ‘Mass Production Mode’, click ‘Pset’ on the right-below, select one of ‘Auto Program’ ‘Verify’ ‘Blank
Check’, then you can fill a number in ‘Target Count’, click ’ok’. This option can makes programming auto-stop
when the number of chips programmed reach the number you has filled. After click ‘Prog’ button in the
toolbar, insert a device in socket. You can forget about the screen and keyboard, just look at LED on the
programmer. The glowing yellow LED indicates that the device has been programmed successfully. Please
remove the device and insert a new device in the ZIF socket. The system will program the new device
automatically.
After entering Mass Production Mode, the mouse and keyboard operation will be denied except Auto
program button in the toolbar. Pressing ‘Prog’again will exit Auto program mold.
Note that if you want Auto program at normal operation mode, please do not keep Mass Production
active.
10.6.4 Slow Program/Read
When standard reading some device, it may failed for programming or reading fallible, due to the
capability of device. In this case, select ‘slow program/readif this option is valid.
Note that: when the result of standard reading is different from slow reading, it means that standard
reading is fallible, only select ‘slow read’.