6.2 Troubleshooting
6.2.1
Error codes
Errors and required responses
The following table lists the errors that you will be able to fix yourself under certain circumstances. If the combi oven keeps
showing the error even after you attempt to fix it, contact Customer Service.
If any error messages other than the ones listed here appear
, contact Customer Service.
Error No. Error description Required response
E01.x
Not enough water Open the water connection valve(s)
E02
El. temperature too high
Clean the fan screen on the bottom of the
unit
Clear the area around the air intake on the
bottom of the unit
E05
No gas Open the gas shut-off device and restart the
unit
E10
Water filter fault Replace the water treatment system cartridge
E34.0
Boiler pump fault Disconnect the unit from the outlet for approx.
10 seconds and restart it
E58.0
Cleaning agent dispensing pump fault
Fill the canister with the appropriate cleaning
agent and restart the unit
If necessary
, repeat until the lines are filled
with cleaning agent
E59.0
Rinse aid dispensing pump fault
Fill the canister with rinse aid and restart the
unit
If necessary
, repeat until the lines are filled
with rinse aid
E81.0
Cooking mode error Write the cooking profile again
E99
Communications dropped out Disconnect the unit from the outlet for approx.
10 seconds and restart it
E99.9
Initialization error Disconnect the unit from the outlet for approx.
10 seconds and restart it
6 How to Perform Maintenance on the Combi Oven