5.4.6 Replacing the Rinse Aid Canister
For your safety when working with/on the combi oven
Before starting work, read and understand the rules, risks, and hazards specified in the 'For Your Safety on page 17' section
and in these instructions and follow all the corresponding instructions without exception.
Required tools
One empty canister (2.5 gallons) for ConvoCare rinse aid
Enough (around 2.5 gallons) soft water (for specifications, please refer to the 'W
ater Quality' sub-section of the 'Technical
Data' section in the installation manual)
ConvoCare Concentrate (0.7 pint)
Preparing ConvoCare rinse aid in the canister
To prevent undesired foaming, follow the steps below when preparing rinse aid with ConvoCare concentrate and soft water:
1.
Open the empty canister (1).
2.
Fill the canister with soft water (2) all the way to just under the 2.5-
gallon marking (4).
3.
Risk of skin, eye, and respiratory tract irritation
Do not let the rinse aid come into contact with your eyes, skin, or
mucous membranes.
Do not inhale the rinse aid's vapors or mist.
W
ear the required personal protective equipment.
Then carefully pour 0.7 pints of ConvoCare Concentrate (3) into the
canister (1).
4.
Check the liquid level inside the canister:
If the level is below the 2.5-gallon marking (4), carefully add the re-
quired amount of soft water (2).
If the level is above the 2.5-gallon marking (4), the rinse aid's con-
centration will be lower than specified. You can still use the rinse aid
if this is the case!
5.
Close the canister and mix the liquids thoroughly by shaking it.
5 How to Clean the Combi Oven
Operating Manual 96