Replacing the Rinse Aid Canister
1.
Risk of skin, eye, and respiratory tract irritation
Do not let the rinse aid come into contact with your eyes, skin, or
mucous membranes.
Do not inhale the rinse aid's vapors or mist.
W
ear the required personal protective equipment.
Remove the cap from the canister in which you prepared ConvoCare
rinse aid.
2.
Find the canister that is connected to the rinse aid connection (F)
with a (green) tube and that is located on the bottom left side of the
unit.
Unscrew the (green) supply tube (2), together with the wand, from
the canister you just identified.
Remove the empty rinse aid canister
.
3.
Put the new
, full canister (1) containing rinse aid in place.
Insert the (green) supply tube, together with the wand (2), into the
full canister (1) and screw it in place.
Make sure that the tube is routed without any kinks and that the vent
opening on the canister's cap is open and clear.
4.
Check to make sure that the canisters are set up correctly:
The canisters' supporting surface must not be higher than the
edge where the feet and the unit case meet.
The canisters' supporting surface must not be more than 3 feet
below this edge.
Check to make sure that the tube is connected to the right connec-
tion.
The rinse aid must go to unit connection F
.
(indicated by a green color).