No. Guard or safety device Function Check
7
(installed by
the customer)
Disconnector Used to de-energize the unit during
cleaning, repairs, and maintenance
work, as well as in hazardous situa-
tions
The operator does not need to check
anything.
8
(installed by
the customer)
Gas shut-off device Used to disconnect the unit from the
gas supply during cleaning, repair
,
and maintenance work, as well as in
hazardous situations
The operator does not need to check
anything.
Safety measures
The following measures will contribute to greater safety:
Measure Function Check
Unit door solenoid switch
(electrical door sensor)
■
Stops/turns of
f the following when the unit
door is opened:
■
Fan (will stop after a few seconds)
■
Heating element
■
Cleaning agent spraying in the fully au-
tomatic oven cleaning process
■
Prompts the user to close the unit door
Test the door solenoid switch with the combi
oven at a low temperature
Procedure:
■
Fully open the unit door
■
Press Start
Result:
The motor must not start running.
Resuming after a power out-
age if there was cleaning
agent inside the unit when
the power went out
■
Starts the fully automatic or semi-automat-
ic oven cleaning process again, from a de-
fined state, after a power outage
None
3 For Your Safety
Operating Manual 30