8 Annual PM check
Back to contents >
Planned preventative maintenance schedule for the
Merrychef eikon
®
e2s commercial combination oven
Daily
12
months
Comments
Item
Description
Commissi
oning
Operator
OCIE
check
See latest parts manual for part
numbers
1
Check installation and surroundings as
per installation instructions
P
P
P
2
Check cook baskets for damage and
replace if required.
P
P
P
For operator to check
3
Check oven cook plate
P
P
If damaged replace cook plate and studs
4
Check air filter and clean
P
P
P
Oven can be damaged if missing
5
Inspect impinger plate, replace as
required
P
Replace every 24 Months or when damaged
6
Inspect partition plate
P
Replace if damaged
7
Visually check oven for damage
P
Document findings
8
Check condition of mains lead and plug
P
Replace mains lead if damaged.
Check oven model for service part number.
9
Clean oven as per user instructions
P
10
Check and clean steam vent pipe
P
11
Check door seal condition and replace
as required
P
P
Replace every 24 Months or when damaged
12
Check door operation
P
P
P
13
Check on/off switch operation
P
P
14
Check oven serial number & firmware
revisions
P
P
Update firmware is older version(s) displayed
15
Check touch screen condition and
operation
P
P
Calibrate if required
16
Check touch screen overlay and replace
as required
P
Replace every 24 Months or when damaged
17
Check date & time
P
P
Update as required
18
Check and record oven counter screen
P
19
Check & record amp draw, heating
element and magnetron(s)
P
20
Check operation oven components
P
21
Check stirrer motor(s) is rotating
P
Listen with all other components switched off
22
Check oven temperature calibration
P
P
Check cavity temperature is in range
23
Unplug and isolate (LOTO)
P
24
Remove all panels and discharge the
HV Capacitor(s)
P
25
Check all internal electrical connections
for tightness and condition
P
26
Check magnetron(s) and cooling duct
P
Replace magnetron(s) every 48 months or
every 1500 Mag Hours
27
Check door switch condition and
adjustment
P
Replace 24 Months or when damaged
28
Vacuum out casework
P
29
Refit all panels and plug the unit in to
the electrical supply. Switch the oven
on
P
30
Check & download error log file
P
31
Download cook count file
P
32
Check for microwave leakage
P
P
33
Complete recommission test and
service report
P
P
34
Pre-heat the oven and cook one item of
food from the operators’ menu.
P
P
P
Total hrs/mins
0.5hrs
1hr
= Mandatory checks that can be completed in visual view and should only take 15min to attend to and record findings in the comments column