WARNING: EVEN THOUGH YOU HAVE LOCKED OUT THE PIVOT CONTROL PANEL
DISCONNECT SWITCH, THERE IS STILL 480 VOLTS PRESENT GOING INTO THE
PANEL BOX.
Locks and Tags
When you purchase lockout/tagout devices, keep the following points in mind:
Lockout devices and tagout devices shall be singularly identied as belonging to only one worker;
shall be the only device(s) used for controlling energy; shall not be used for other purposes.
Tagout devices shall warn against hazardous conditions if the pivot is energized and shall include
a legend such as the following: DO NOT START, DO NOT OPEN, DO NOT CLOSE, DO NOT EN-
ERGIZE, and DO NOT OPERATE. Attachment devices for tags shall be non reusable and have a
minimum of 50 lb. (222 N) breaking strength.
Locks used to lockout machines or equipment shall have a key unique to that lock.
Using Tags without Locks
There are limitations to the tagout system. Since tags are warning devices only, they must meet
the following requirements:
They must be legible. (If you employ migrant workers, the tags should also be bilingual.)
They must not be removed, bypassed, or ignored.
They must be sturdy enough to withstand the elements and be securely attached.