This kit may be used with the following Mira Advance Shower:
Mira Advance Flex Extra 8.7kw 1.1785.005 (J09N)
Installation guidelines for Models
SDP134T Whale INSTANT MATCH
®
with Bluetooth
®
wireless technology Kit
300,000
WHALE KITS INSTALLED IN THE UK
Please leave this booklet with the end user
after installation and demonstration
181.604 (IMATCH).qxp_Layout 1 14/10/2019 11:24 Page 1
Question and Answer IconNeed help?

Do you have a question about the Whale INSTANT MATCH SDS263T and is the answer not in the manual?

Summary

Installation Guidelines

User Warnings

End User Help

Troubleshooting steps and guidance for end users.

Principles of Operation

Installation Warnings

Plumbing Specification

Plumbing Gulley

Wet Floor Gulley Installation

Specific instructions for installing the wet floor gulley.

Tray Gulley Installation

Specific instructions for installing the tray gulley.

Plumbing of Waste Pipe

Use with Macerator Pump

Guidance on connecting the pump to a macerator.

Installation

Plumbing Drainage Pipe

Instructions for connecting the drainage pipe.

Locating Pump on Wall

Advice on selecting the optimal location for the pump.

Mounting Pump to Wall

How to securely mount the pump backplate to the wall.

Plumbing Connections

Details on making the pipework connections to the pump.

Wiring the Transformer

Connecting the mains power to the transformer.

Activelink Diagnostics

Explanation of indicator LEDs and diagnostic features.

Fit and Secure Pump Cover

Instructions for fitting and securing the pump cover.

Optional External Pump Overrun Switch

Information on installing an optional external pump switch.

Transformer Settings

How to configure the transformer settings for different sensors and pipe sizes.

Bluetooth Wireless Technology

Important Bluetooth Information

Key details regarding Bluetooth compatibility and placement.

Shower Settings for Bluetooth

Configuring shower settings for Bluetooth operation.

Transformer Setup for Bluetooth

Steps to set up the transformer for Bluetooth pairing.

Configuring Shower for Pairing

How to turn on the shower to complete the pairing process.

Bluetooth Wireless Technology Unpairing

Power Off for Unpairing

Initial step to switch off the mains power supply.

Transformer Light Status

Observing the transformer light after power cycle.

Unpairing Procedure

Final steps to complete the unpairing process.

Unpairing Mira Advance Shower

Specific steps for unpairing the Mira Advance shower.

Initial Unpairing Steps

Isolating power and adjusting DIP switches for unpairing.

Power Cycle Shower

Turning the shower power on to complete the cycle.

Hardwired Setup

Transformer Setup for Hardwiring

Configuring the transformer for a hardwired connection.

Shower Settings for Hardwiring

Adjusting shower settings for hardwired operation.

Connecting to Mira Advance Shower

Wiring the signal cable from transformer to shower.

Connecting to Other Whale Transformers

Compatibility guide for older Whale transformers.

Purge Cycle

Swapping Pump and Transformer Location

Safety Warning

Installation Testing and Repair

Test Pump Suction

How to test the pump's suction capability.

Rodding Pipework

Method for clearing blockages in pipework.

External Pipework Test

Testing external pipework for issues.

Air Leak Test

Procedure to check for air leaks in the system.

Flow Rate Testing

Method for measuring shower flow rate.

Check Tricuspid Valve

Inspecting and replacing the tricuspid valve.

Check Inside Pump Head

Inspecting the pump head for debris and diaphragm seating.

EU Declaration of Conformity

Statement of Limited Warranty

Product Specification

List of Parts Included

Spares and Accessories

Pump Base Standoffs

Fault Diagnosis

Pump Will Not Start

Steps to diagnose why the pump fails to start.

Pump Will Not Stop

Steps to diagnose why the pump continues to run.

Wired Connection Faults

Diagnosing issues with hardwired connections.

Bluetooth Connection Faults

Diagnosing issues with Bluetooth connectivity.

Pump Not Pumping Properly

Troubleshooting for when the pump runs but doesn't pump effectively.

Pump Cover and Transformer Dimensions

Pump SDS021 T Dimensions

Overview

The Whale Instant Match® with Bluetooth® wireless technology Kit (SDP134T) is a pumped shower drainage system designed to efficiently remove waste water from shower areas, particularly in installations where gravity drainage is not feasible or sufficient. This kit is a market leader in its category, known for its reliability and minimal maintenance requirements.

Function Description:

The core function of the Whale Instant Match® system is to pump shower waste water. It utilizes a Bluetooth® wireless technology control unit that monitors the flow rate of water into the shower via a flow sensor. Based on these signals, the control unit adjusts the pump speed to match the incoming water flow, thereby minimizing suction noise at the gulley. When the shower is turned off, the flow sensor signals the control unit, and after a pre-set time delay, the pump switches off. An additional feature is a purge cycle: 15 minutes after the shower is turned off, the pump automatically switches on for a short period at a reduced speed to remove any residual run-off water pooled in the shower area, ensuring the area remains dry. The pump is designed to run dry without sustaining damage, and non-return valves in the pump head prevent unpleasant smells from entering the bathroom from the waste pipe.

Important Technical Specifications:

Pump (Model: SDS021T):

  • Dry running current: 1.2 amp
  • Maximum Head: 1.0m
  • Maximum lift: 500mm
  • Maximum Head & Lift: 1.5m
  • IP Rating: IP45 compliant, suitable for installation in bathroom zones 1, 2, or 3 (according to BS7671 2008 Part 7, 17th Edition).
  • Maximum flow rate: 8 litres per minute (ltrs/min) for 15mm inlet pipe, and 12 lpm for 22mm inlet pipe (for mixer showers).
  • Pipework: 15mm pipe from gulley to pump inlet (max 3m). 22mm pipe for pump outlet.
  • Gulley Fall: Minimum 1:40 fall from shower base to gulley.
  • Pump Inlet/Outlet Height: Not more than 500mm off the floor.

Transformer (Model: SDS236T / 755.678):

  • Power: 75 Watts average
  • Class: 1
  • Mains cable: 1.8m (3 core)
  • Low voltage cable: 2.0m (2 core)
  • Sensor type selector: Settings for Aux, Sika, Gems (1000ppl, 2200ppl), Venturi, Mira Wired, and Bluetooth. Factory set to Bluetooth.
  • Off Delay: Selectable settings of 10, 30, and 60 seconds. Factory set to 10 seconds.
  • Pipe Inlet Diameter: Selectable settings for 15mm (electric showers only) and 22mm (mixer showers). Factory set to 15mm.
  • Bluetooth® Wireless Technology: For optimal signal strength, the transformer should be mounted within 5 meters of the shower in the same room. Plastic access panels are recommended if installed in boxing. Hardwired connections are advised if the transformer is outside the bathroom area.
  • Activelink Diagnostics: Includes two indicator LEDs (blue for power on, green for water flow) and a test button with an audible buzzer for installation aid.

Usage Features:

  • Automatic Operation: The system automatically activates and adjusts pump speed based on shower water flow, and deactivates after a pre-set delay once the shower is off.
  • Purge Cycle: An automatic 30-second pump activation at a lower flow rate 15 minutes after the shower is used, to clear residual water and keep the shower area dry.
  • Optional External Pump Overrun Switch: A retractive switch (available separately) can be installed outside the wet area to manually activate the pump for 15 seconds at full speed, useful for cleaning or ritual cleansing.
  • Bluetooth® Wireless Technology: Enables wireless communication between the transformer and compatible Mira Advance Flex Extra (J09N) showers for seamless operation.
  • Hardwired Connection Option: For installations where wireless communication is not ideal, the system can be hardwired to the Mira Advance Flex Extra (J09N) shower.
  • Adjustable Settings: The transformer allows for adjustment of flow sensor type, off delay, and pipe inlet diameter to suit specific installation requirements.

Maintenance Features:

  • Accessibility: All electrical and mechanical components (transformer and pump) must be accessible after installation for inspection and service.
  • Fault Diagnosis Flowchart: A comprehensive flowchart is provided in the manual to assist in troubleshooting common issues such as the pump not starting or not stopping, and the pump not pumping properly.
  • Component Inspection: Instructions are given for checking the tricuspid valve and inspecting the pump head for debris or diaphragm issues.
  • Pipework Checks: Guidance on checking for blockages, air leaks, and ensuring airtight fittings.
  • Spare Parts Availability: A list of spare parts and accessories is provided, including replacement head kits, diaphragms, tricuspid valves, and flow sensors, which can be ordered from a distributor.
  • Technical Helpline: A dedicated technical helpline is available for further assistance.
  • Online Resources: Installation videos and troubleshooting guides are available on the Whale website and YouTube channel.
  • Warranty: The product comes with a 3-year limited warranty, extendable to 5 years upon warranty registration.

Whale INSTANT MATCH SDS263T Specifications

General IconGeneral
BrandWhale
ModelINSTANT MATCH SDS263T
CategoryPlumbing Product
LanguageEnglish

Related product manuals