www.whisperkool.com | Page 17
Phantom Series
PREPARING THE UNIT FOR INSTALLATION
The WhisperKOOL unit requires a dedicated 115V, 20-amp circuit. The unit draws a large amount of amps during its initial
startup. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to run eectively. Contact an
electrician for assistance with the installation of this dedicated electrical circuit.
The unit must sit upright for 24 hours prior to installation. To prepare the unit for installation:
Remove unit from box.
Match the electrical outlet to the plug provided on the WhisperKOOL unit.
Provide a dedicated circuit and wiring for the unit (see above).
Provide a weatherproof plug for units connected outside.
Power surges and spikes can damage sensitive electrical equipment. WhisperKOOL recommends plugging the unit into a surge
protector or power conditioner in order to protect your system. As outlined in our terms and conditions, power surges and spikes
are not covered under warranty.
Do not use a GFI (ground fault interrupter) with this product.
In case the unit should lose power, check the home/main circuit breaker. If the unit does not respond properly, refer to the
Troubleshooting Guide.