Kunststoffschweißtechnik
Starting and operating Chapter 5
20.08.14 Working instructions WIDOS 3511 Page 21 of 39
Secure this position with the clamping lever.
Press the stop watch for the heating time.
After expiration of the heating time release the clamping lever, open the machine quickly,
swivel out the heating element and drive the slides together immediately shock-free and
with minor force until the dial rests against the stop bolt (change-over time). The maximum
time frame for this process is predetermined by the value for the change-over time taken
from the table.
Secure the position by clamping lever (8) and press the stop-watch.
Now, the cooling time starts. After expiration of the cooling time open the clamping tools
and remove the welded part.
Release the clamping lever and open the machine.
The welding process is completed
Complete the weld log (chapter 6).