WIKA operating instructions pressure gauge, model 2 per ATEX18
14375375.01 12/2019 EN/DE
2.7 Ignition hazard analysis
Relevantidentiedignition
hazards
Implementedprotectivemeasures
Hot surfaces
The actual surface temperature depends
on the application, i.e. on the medium
temperature
Temperature range marking; T range
marking
Observation of legibility of marking
Information given in operating instructions
Mechanically generated sparks
and hot surfaces
Low contact speed
Limitation of vibration
Selection of suitable materials
Information given in operating instructions
Stray electric currents, cathodic
corrosion protection
Grounding via process connection required
Information given in operating instructions
Static electricity
No propagating brush discharge
All conductive parts bonded
Limitation of projected area of non-conduc-
tive parts
Limitation of layer thickness of non-conduc-
tive parts
Grounding via process connection required
Description of cleaning process
Information given in operating instructions
Exothermic reactions, including
self-ignition of dusts
Provision of material data of the wetted
parts for the customer in order to avoid the
use of critical media
Information given in operating instructions