Do you have a question about the Wiltronics ME2100 and is the answer not in the manual?
Type | Digital Multimeter |
---|---|
Diode Test | Yes |
Display | 3.5 digit LCD |
Operating Temperature | 0°C to 40°C |
AC Voltage Ranges | 200V |
DC Current Ranges | 200µA, 2mA, 20mA, 200mA, 10A |
Resistance Ranges | 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ |
Continuity Test | Yes |
Measurement Range | Depends on function and range selected |
Resolution | Varies depending on the function and range selected |
Power Supply | 9V battery |
Lists all components included in the ME2100 moisture meter kit for user reference.
Illustrates the internal components, ports, and indicators of the ME2100 meter.
Details the primary and secondary functions of each key on the ME2100 meter keypad.
Explains the various data fields and prompts displayed on the ME2100 meter screen.
Describes the operation, advantages, and accuracy of the meter's Lab Mode.
Procedure for meter startup and automatic fuel cell integrity test.
Steps for inputting location codes and selecting fuel types for measurement.
Final check for sample cell cleanliness before conducting moisture measurements.
Steps for grinding fuel samples and loading them into the meter's test cell.
How to start the moisture measurement and store the results.
Cleaning the test cell and repeating measurements for improved accuracy.
Guidelines on cleaning frequency and approved agents for maintaining test cell accuracy.
Instructions on how to navigate and view previously stored moisture readings.
Steps to retrieve data and parameters from the meter to the ME2100 Manager software.
Procedures for editing existing or importing new fuel parameters within the software.
Process for transferring modified parameters back to the ME2100 meter.
How to edit, add, or delete fuel types within the software's fuel parameter list.
Procedure to clear all stored measurements and reset the meter's counter.
Details on battery operation, low voltage indicators, and charging methods.
Guidance on returning the meter for annual maintenance and calibration services.
Details the physical size, weight, and materials used in the ME2100 meter.
Outlines the meter's operational performance parameters and communication interface details.
Relates Eucalypt fuel moisture content to fire behaviour characteristics.
Relates Radiata Pine fuel moisture content to fire behaviour characteristics.
Table showing minimum and maximum moisture content readings for various fuel type groups.
Classifies fuel condition (Fresh, Green, Brown, Grey, Fragmented) for calibration.
Provides calibration coefficients and their application to fuel groups.
Maps various species and their leaf conditions to specific meter calibration coefficients.
Steps to physically connect the ME2100 meter to a PC using the provided USB cable.
Troubleshooting steps for issues encountered during USB serial port driver installation.
Guide to establishing and verifying communication between the ME2100 meter and PC using ME2100 Manager.