52 86317500 CHARIOT SCRUBBER
Maintenance
PROBLEM CAUSE SOLUTION
Vacuum motor does not run, or
runs slowly
Faulty vacuum circuit or switch Check wires & connections
Worn vacuum motor brushes Replace brushes, check commutator
Squeegee will not go up/down Faulty circuit or actuator Check wires, connectors and actuator
Faulty cables or pulleys Repair/replace cables or pulleys
Poor scrubbing performance Debris caught in scrub brushes Remove debris
Worn brushes or pads Replace brushes or pads
Improper detergent, brush or pad used
Contact equipment or application
specialists
Low scrub brush down pressure Increase brush pressure
Low battery charge Charge batteries
Little or no solution flow to the
floor
Solution tank empty Fill solution tank
Solution strainer plugged Clean solution strainer
Solution system plumbing obstructed Clear obstruction from plumbiing
Pump obstructed Clean or replace pump
Solution solenoid valve obstructed or
stuck
Solution solenoid valve obstructed or
stuck
Solution shut-off valve is closed Open shut-off valve
Faulty pump circuit or pump Check wiring, connections, and pump.
Faulty solenoid Check solenoid valve
Brush motors do not run, or run
slowly
Circuit breaker(s) tripped Reset circuit beaker(s)
Low battery charge Charge battery
Faulty brush circuit or motor Check wires, connections and motor
Worn brush motor brushes
Replace brushes, check commutator
Scrub deck goes down, then
raises
Faulty actuator circuit or actuator Faulty actuator circuit or actuator
No brushes or pad drivers on machine
Install brushes or pad drivers