Maintenance
Changing Batteries
Stop the machine in a clean area next to the charger.
Turn off machine.
FOR SAFETY: Before leaving or servicing the
machine; stop on level surface, turn off machine
and remove key.
1. Remove the rear cover.
2. Turn off breaker and disconnect battery pack from
machine.
3. Unlatch battery tray from machine and pull out to
expose batteries.
4. Use the proper size open end wrench to discon-
nect main ground wire first and secure cable
terminal away from batteries.
5. Disconnect main positive lead and secure cable
terminals away from batteries.
6. Loosen both terminals on each jumper cable and
remove one at a time.
7. Prepare a suitable site to place the batteries.
8. Remove batteries from machine.
Attach suitable battery lifting device and lift
batteries from the machine. Batteries are a
potential environmental hazard. Consult your
battery supplier for safe disposal methods.
Fixez le dispositif de levage de batterie approprié et
levez les batteries de la machine. Les batteries
constituent un danger potentiel pour l'environne-
ment. Consultez le fournisseur de votre batterie
pour connaître les méthodes d'élimination sûres.
+
--
++
-
RED
BLK
RED
BLK
RED
BLK
REAR OF MACHINE
8.641-374.0 operator’s manual - chariot 3 - cv86/1 rs bp