Display messages
87
Problem Rectifi cation measure
The brewing unit cannot
be removed or reinserted
>Adjust the brewing unit with the multitool as you are
inserting it until you can insert the brewing unit.
>Remove the residue of coffee grounds inside the brewer.
There is a noticeable large
amount of coarse ground
coffee inside the brewer
>Set the grinding grade fi ner by one rotation (chapter “3.6.3 Grinding
grade setting: Perfect Extraction System” on page 40).
Is the metal spring ring in the brewer stamp missing?
>Release the brewing unit (3a).
>Use the multitool (3b) to turn the brewer (3c) clockwise all the way upwards.
The brewer stamp (3d) on the bottom of the brewer is now visible.
>Insert the metal ring (3e) in the brewer stamp (3d).