16. HG control parameters
No.: Description:
Factory settings
28 kW 35 kW
Natural
gas
LPG
Natural
gas
LPG Min. Max.
H34 eBUS feed 1 1 1 1 0 1
H37 Pump control type (constant = 0; spread ΔT = 1) 1 1 1 1 0 1
H38 Set spread, pump control °C 15 15 15 15 1 30
H39 Time, soft start min 3 3 3 3 0 10
H40
System congura-
tion
1 = Direct heating circuit
2 = Mixer module
(no direct heating circuit)
60 = Cascade module
(no direct heating circuit)
1 1 1 1 1 60
H41
Speed, feed/heating circuit pump for DHW
(only shown if H51 = 1, 2, 3)
% 95 95 95 95 15 100
H51 DHW conguration
1 = Combi mode
1/4 1/4 1/4 1/4 1 4
2 = Combi mode + solar
3 = Cylinder mode
4 = No DHW
(heating mode only)
H52
2)
Pasteurisation function
(only shown if H51 = 3)
°C 5 5 5 5 0 80
H53
2)
Activation interval, pasteurisation function
(only shown if H51 = 3)
Days 7 7 7 7 1 7
H54
2)
Heating curve 0 0 0 0 0 30
H55
2)
DHW quick start
(only shown if H51 = 1.2)
0 0 0 0
0
Eco
1
Comfort
A09
2)
System frost protection °C 2 2 2 2 -20 10
1)
Parameters H02 - H04 are automatically modied by adjusting value H12 (gas / output selection)
2)
If a BM-2 is installed, parameters H52 - A09 can only be set in the BM-2
ParametersH12,H40andH51mustbespeciedatthestartofcommissioningorshouldbesetin
advance.