Page #13 background imageLoading...
Page #13 background image
Diagnostics and Maintenance
Diagnostics - Receiver
Diagnostics and Maintenance doc021820 2-2
2
2.1 Diagnostics - Receiver
Signal lights are located on the side wall of the receiver.
Operation
Control light
Yellow
Operation
Control light
Green
Signal
Control light
Red
Error
Control light
Orange
Normal
Receiver is turning on On
Blinks every
0.5 sec.
Off Off Off
Receiver is turned off Off Off Off Off
The transmitter is
turned off
Receiver is on
On
Blinks every
0.5 sec.
Off Off Off
The transmitter and
receiver
communicate.
On
Blinks every
0.5 sec.
On
Blinks fast
Off On
START button is not
pressed
On
Blinks every
0.5 sec.
On
Blinks fast
Off Off
(The light is on when
joysticks on the
transmitter are not in
the neutral position)
E-stop button is
pressed
when receiver is on.
On
Blinks every
0.5 sec.
On
Blinks fast
Off Off
The transmitter and
receiver do not
communicate.
On
Blinks every
0.5 sec.
Off Off Off

Other manuals for Wood-mizer LT70 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wood-mizer LT70 Series and is the answer not in the manual?

Wood-mizer LT70 Series Specifications

General IconGeneral
Hydraulic Log HandlingOptional
Computer SetworksOptional
Blade Width1.5 inches (3.8 cm)
Power OptionsElectric or diesel
Head ControlsManual
Cutting MethodHorizontal bandsaw