Maintenance
Safety Devices Inspection (European Union Market only)
Maintenance doc050624 5-20
5
2. Cutter cover safety switch and its circuit inspection
CAUTION! Use extreme caution when opening cutter
housing cover if any of the cutters are working (to inspect
safety devices).
Be sure the emergency switch button is released;
Use “I” buttons to start all cutters and next feed rollers. The motors should start.
Open the cutter housing cover;
All motors should be stopped.
Pressing any of “I” buttons should not start the motors.
Close the cutter housing cover.
Motors should remain stopped until they are restarted with any of “I” buttons.