Maintenance
Safety Devices Inspection (European Union Market only)
5
5-19 doc050624 Maintenance
5.13 Safety Devices Inspection (European Union Market only)
MP280S Moulder – Safety Devices Inspection
Safety devices on the machine which must be checked before every shift:
E-STOP button and its circuit inspection,
Cutter cover safety switch and its circuit inspection.
1. E-STOP button and its circuit inspection
Use “I” buttons to start all cutters and next feed rollers. The motors should start.
Press the E-STOP button located on the control box. All motors should be stopped.
Pressing any of “I” buttons should not start any motor until the E-STOP button is
released.
FIG. 5-1