2. Wiring and Communication Configuration
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher. Read
through this section in this entirety before running or terminating the wires to ensure proper operation and to avoid damaging
equipment.
2.1 RS-232 Connections
The following wiring diagrams show the pinouts for the switcher. While not shown, connect the TX (transmit) to RX (receive) pins at
the control system or PC side of the cable. Most control systems and computers are configured for Digital Terminal Equipment
(DTE) where pin 2 is RX and pin 3 is TX This can vary from device to device, refer to the documentation for the connected device for
pin functionally to ensure that the connect connections can be made.
2.2 Serial and IP Settings
Baud rate:
115200
Data Bits:
8bits
Parity:
None
Stop Bits:
1bit
Flow Control:
None
Default IP Address:
192.168.11.43
Default IP Port:
23
3. Command Overview
Command Type:
Key Words:
[Prm]:
[Input]:
Command termination: