Configure Serial Power On/Off for Display
SET UART_PWR all [Prm] rx<CR><LF>
Response: UART_PWR SET all [Prm] rx<CR><LF>
Example: SET UART_PWR all on rx<CR><LF>
Response: UART_PWR SET all on rx<CR><LF>
[Prm] = on | off
Configure Serial Auto Power On/Off for Display
Set Serial Auto Power On/Off
SET UARTPWR_FN all [Prm] rx<CR><LF>
Response: UARTPWR_FN SET all [Prm] rx<CR><LF>
Example: SET UARTPWR_FN all on rx<CR><LF>
Response: UARTPWR_FN SET all on rx<CR><LF>
Query Serial Auto Power On/Off
GET UARTPWR_FN all dev<CR><LF>
Response: UARTPWR_FN GET all [Prm] rx<CR><LF>
Example: GET UARTPWR_FN all rx<CR><LF>
Response: UARTPWR_FN GET all on rx<CR><LF>
[Prm] = on | off
Configure Serial Power Delay Time
Set Serial Power Delay Time
SET UARTPWR_D all [Prm] rx<CR><LF>
Response: UARTPWR_D SET all [Prm] rx<CR><LF>
Example: SET UARTPWR_D all 2 rx<CR><LF>
Response: UARTPWR_D SET all 2 rx<CR><LF>
Query Serial Power Delay Time
GET UARTPWR_D all dev<CR><LF>
Response: UARTPWR_D GET all [Prm] rx<CR><LF>
Example: GET UARTPWR_D all rx<CR><LF>
Response: UARTPWR_D GET all 2 rx<CR><LF>
[Prm] = 1~30 In Minutes with a default of 2min
Note: Setting the UART POWER Delay Time via RS232 allows the sink to be powered off at a specific period of time when there’s no source input and
be powered on immediately once detecting an input.