© Copyright 2018 WyreStorm Technologies | WyreStorm.com
EX-SW-0301-H2 API | 180619-1616
7 of 13
North America: 844.280.WYRE (9973) | UK/EMEA: +44 (0) 1793 230 343
Email: Support@WyreStorm.com
Relay Timing
SET MOMENT_T [Prm] rx<CR><LF>
Response: MOMENT_T SET [Prm] [Device]<CR><LF>
Example: SET MOMENT_T 8 rx<CR><LF>
Response: MOMENT_T SET 8 rx<CR><LF>
Query Momentary Time
GET MOMENT_T rx <CR><LF>
Response: MOMENT_T GET [Prm] rx<CR><LF>
Example: GET MOMENT_T rx<CR><LF>
Response: MOMENT_T GET 8 rx<CR><LF>
[Prm] = 1 ~ 10 // seconds | default is 3s
4.5 Configuring CEC
CEC Power On/Off
SET CEC_PWR all [Prm] rx<CR><LF>
Response: CEC_PWR SET all [Prm] [Device]<CR><LF>
Example: SET CEC_PWR all on rx<CR><LF>
Response: CEC_PWR SET all on rx<CR><LF>
[Prm] = on | off
CEC AUTO POWER ON/OFF
Set CEC AUTO POWER ON/OFF
SET AUTOCEC_FN all [Prm] rx<CR><LF>
Response: AUTOCEC_FN SET all [Prm] rx<CR><LF>
Example: SET AUTOCEC_FN all on tx<CR><LF>
Response: AUTOCEC_FN SET all on tx<CR><LF>
Query CEC AUTO POWER ON/OFF
GET AUTOCEC_FN all rx<CR><LF>
Response: AUTOCEC_FN GET all [Prm] rx<CR><LF>
Example: GET AUTOCEC_FN all rx<CR><LF>
Response: AUTOCEC_FN GET all on rx<CR><LF>
[Prm] = on | off
CEC POWER Delay Time
SET AUTOCEC_D all [Prm] rx<CR><LF>
Response: AUTOCEC_D SET all [Prm] rx<CR><LF>
Example: SET AUTOCEC_D all 2 rx<CR><LF>
Response: AUTOCEC_D SET all 2 rx<CR><LF>
Query CEC POWER Delay Time Status
GET AUTOCEC_D all rx<CR><LF>
Response: AUTOCEC_D GET all [Prm] rx<CR><LF>
Example: GET AUTOCEC_D all rx<CR><LF>
Response: AUTOCEC_D GET all 2 rx<CR><LF>
[Prm] = 1~30 In Minutes with a default of 2min