7.4 Establishing Communication with the Scaler
In order to establish communication with the scaler, the COM port that is used on the PC must be selected. The port number must
match the port configured in the Configuring the PCs COM Port section.
1. Power on the SW-0402-MV-HDxx and wait for the unit to initialize. The lights on the front will stop cycling and become solid
once the unit is initialized.
2. Power on the PC and open the SW-0402 Console.
3. Open the drop down list next to COMM: and select the appropriate COM Port number on the PC.
4. The black dot next to COMM: will turn red when the PC is communicating with the SW-0402-MV-HDxx.
7.5 Configuring EDIDs
EDID (Extended Display Identification Data) is data generated by a display device that communicates the capabilities of the device
(720p, 2ch Audio, 1080p, 7.1ch Audio).
For communication between devices to be successful, devices must both request and send the required information. For example, a
display will communicate 1080p capability with 2ch audio, the source device will then accept and output the correct format for the
display. Problems can arise when different devices such as displays with different performance specifications are used within a
system.
EDIDs can be set within the PC Console to allow for displays and sources to communicate properly and output audio and video
correctly.
To Configure EDIDs
1. Open the PC Console.
2. Navigate to the EDID tab.