System Specifications
86 Freedom XC Owner's Guide
System Specifications
Freedom XC 1000 Freedom XC 2000
Transfer relay rating (A
a
) 30A (24A continuous)
Transfer time (milliseconds
b
)
Shore to inverter:
Inverter to shore:
<20milliseconds
<20milliseconds with a 20-second delay
Transfer voltage (V)
Shore to inverter:
Inverter to shore:
<85V and >140V
<135V and >90V
Cooling
Fan, activated by any of the following:
High internal temperature
High AC output power
Table 19System specifications
a
Circuit breakers shall not carry more than 80% of their UL current rating continuously.
b
To change the AC Transfer time (mode), see Adjusting Settings in Configuration Mode on page 51.