System Specifications
975-0799-01-01 93
System Specifications
Freedom XC PRO 2000 Freedom XC PRO 3000
Transfer relay rating (A
a
) 30A 50A
Transfer time (milliseconds
b
)
Shore to inverter:
Inverter to shore:
<20milliseconds
<20milliseconds with a 20-second
delay
<20milliseconds
<20milliseconds with a 20-second
delay
Transfer voltage (V)
Shore to inverter:
Inverter to shore:
<85V and >140V
<135V and >90V
<85V and >140V
<135V and >90V
Cooling
Fan, activated by any of the following:
High internal temperature
High AC output power
Fan, activated by any of the following:
High internal temperature
High AC output power
Table 19System specifications
a
Circuit breakers shall not carry more than 80% of their UL rating continuously.
b
To change the AC Transfer time (mode), see Freedom XC PRO Unit on page 78.