EasyManuals Logo

Xinje DF3E Series User Manual

Xinje DF3E Series
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
9
Servo Drive Orientation
Install the servo drive perpendicular to the wall so the front panel containing connectors faces outward.
Cooling
As shown in the figure above, allow sufficient space around each servo drive for cooling by cooling fans or
natural convection.
Side-by-side Installation
When install servo drives side by side as shown in the figure above, make at least 10mm between and at least
50mm above and below each servo drive. Install cooling fans above the servo drives to avoid excessive
temperature rise and to maintain even temperature inside the control panel.
Environmental Conditions in the Control Panel
Servo driver working ambient Temperature: -10~40
Humidity: 90%RH or less
Vibration: 4.9m/s
2
Condensation and Freezing: None
Note: when installing horizontally (mask facing the operator), it needs to use the frame provided by our company
(see chapter 2.4 the outline dimensions of servo driver).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DF3E Series and is the answer not in the manual?

Xinje DF3E Series Specifications

General IconGeneral
BrandXinje
ModelDF3E Series
CategoryServo Drives
LanguageEnglish

Related product manuals