EasyManuals Logo

Xinje DF3E Series User Manual

Xinje DF3E Series
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
20
SW7 and SW8 control whether the RS485 internal terminal resistance is on:
RS485 internal terminal resistor
SW7=ON SW8=ON
ON
SW7=OFF SW8=OFF
OFF
SW9, SW10 control whether CAN internal terminal resistor is on:
CAN 内部终端电阻
SW9=ON SW10=ON
ON
SW9=OFF SW10=OFF
OFF
3.1.4 Communication port
CN0 port
LAN port
Pin
Definition
1
CANH
2
CANL
3
GND
4
485A
5
485B
6
485GND
Others
Reserved
CANopen default communication parameters: baud rate500kbps.
RS-232 port
5
1
Driver side -5-pin trapezoidal
interface
Pin
Name
Explanation
1
TXD
RS232 send
2
RXD
RS232 reveive
3
GND
RS232 ground
Note: please use the special cable provided
by Xinje company.
RS232 port default communication parameters: baud rate 19200bps, data bit is 8-bit, stop bit is 1-bit, even parity.
Modbus station no.
Parameter
Function
Default
setting
Range
Modification
Effective
P7-10
Modbus station no.
1
1~255
Servo bb
At once
Note: it supports standard Modbus RTU protocol and is used as Modbus RTU slave.
reserved
reserved
485GND
485B
485A
GND
CANL
CANH

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DF3E Series and is the answer not in the manual?

Xinje DF3E Series Specifications

General IconGeneral
BrandXinje
ModelDF3E Series
CategoryServo Drives
LanguageEnglish

Related product manuals