105
12
0
E-120
Current
sensor error
Current sensor
damaged or external
interference too
large
Check the ground wiring or
contact us
1
E-121
U phase
current
sampling zero
calibration
value error
Current sensor
damaged or external
interference too
large
Check the ground wiring or
contact us
2
E-122
V phase
current
sampling zero
calibration
value error
Current sensor
damaged or external
interference too
large
Check the ground wiring or
contact us
13
0
E-130
Motor
quadrature
encoder AB
or UVW
broken circuit
AB or UVW broken
circuit
Cut off the drive power,
Check the wiring, then
repower the drive
14
2
E-142
Motor
encoder Z
phase
disconnected
Z phase
disconnected
Cut off the drive power,
Check the wiring, then
repower the drive
15
0
E-150
Motor
encoder
UVW phase
disconnected
UVW phase
disconnected
Check the wiring of UVW
16
0
E-160
Motor output
Motor output power
1. Change larger power motor

Other manuals for Xinje DS3E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS3E Series and is the answer not in the manual?

Xinje DS3E Series Specifications

General IconGeneral
BrandXinje
ModelDS3E Series
CategoryServo Drives
LanguageEnglish

Related product manuals