EasyManua.ls Logo

Xinje DS3E Series

Xinje DS3E Series
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
105
12
0
E-120
Current
sensor error
Current sensor
damaged or external
interference too
large
Check the ground wiring or
contact us
1
E-121
U phase
current
sampling zero
calibration
value error
Current sensor
damaged or external
interference too
large
Check the ground wiring or
contact us
2
E-122
V phase
current
sampling zero
calibration
value error
Current sensor
damaged or external
interference too
large
Check the ground wiring or
contact us
13
0
E-130
Motor
quadrature
encoder AB
or UVW
broken circuit
AB or UVW broken
circuit
Cut off the drive power,
Check the wiring, then
repower the drive
14
2
E-142
Motor
encoder Z
phase
disconnected
Z phase
disconnected
Cut off the drive power,
Check the wiring, then
repower the drive
15
0
E-150
Motor
encoder
UVW phase
disconnected
UVW phase
disconnected
Check the wiring of UVW
16
0
E-160
Motor output
Motor output power
1. Change larger power motor

Other manuals for Xinje DS3E Series

Related product manuals