56
5-2. Display status
Speed and Torque Control Mode
A. Bit display contents
Bit Data
Description
P5-39
Speed Coincidence
(/V-CMP)
Light when the motor actual speed and command
speed is the same. Speed coincidence signal checking width:
P5-04 (unit: rpm)
P5-42
Torque Limit (/CLT)
Light when actual torque exceeds preset value.
Forward Torque Limit: P3-28
Reverse Torque Limit: P3-29
P5-40
Rotation Detection
(/TGON)
Light when the motor speed exeeds the rotation detection speed.
Rotation Detection Speed Level: P5-03(Unit: rpm)
P5-31
Zero Clamp
(/ZCLAMP)
Light when zero clamp signal is ON.
P5-43
Speed Limit (/VLT)
Light when actual speed exceeds preset value.
Forward speed limit during Torque Control: P3-16, reverse speed
limit: P3-17