39
PLC, SCM, etc. servo drive
When upper device is 5V differential output, please use this wiring diagram.
Please note: P+24V and D+24V must be vacant.
SI input signal
Please use relay or open collector transistor to connect. When using relay, please choose
micro-current relay. Otherwise, the contact will be not good.
Type
Input terminal
Function
Digital input
SI1~SI5
Multi-functional input
Default setting of SI input terminal
Terminal
SI1
SI2
SI3
SI4
SI5
Function
/S-ON
/ALM-RST
/P-OT
/N-OT
Not distribute
P+24V
PUL+
PUL-
P-
R=3.3K
DIR-
D-
R=3.3K
P+5V
D+5V
Shield layer
0V
D+24V
DIR+