P0-25
Power Value of
Discharge Resistance
W
Set as
model
1~65535
1|2|3|4|5|6|
7|8|9|10
5.2.6
P0-26
Discharge resistance
value
Ω
Set as
model
1~500
1|2|3|4|5|6|
7|8|9|10
5.2.6
P0-27
Servo shutdown the
enable stop mode
0-Inertial Operation Stop
2-deceleration stop
-
0
0~5
1|2|3|4|5|6|
7|8|9|10
5.2.4
P0-28
Servo Overrun Stop
Mode
(P0-28.0)
0-deceleration stop 1
1-Inertial Stop
2-deceleration stop 2
3-Alarm Stop
Overtravel alarm shield
switch (P0-28.1)
0-not shield the alarm
1-shield the alarm
-
2
0~3
1|2|3|4|5|6|
7|8|9|10
5.2.4
0
0~1
P0-29
Servo Alarm Stop Mode
0-Inertial Operation Stop
2-deceleration stop
-
2
0~2
1|2|3|4|5|6|
7|8|9|10
5.2.4
P0-30
stop timeout time
1ms
20000
0~65535
1|2|3|4|5|6|
7|8|9|10
5.2.3
P0-31
Deceleration stop time
1ms
25
0~5000
1|2|3|4|5|6|
7|8|9|10
5.2.3
P0-33
Set the motor code
-
0
0~ffff
1|2|3|4|5|6|
7|8|9|10
4.7
Parameter
Function
Unit
Default
value
Range
Effective
Suitable
mode
Reference
chapter
P0-53
Read motor parameter
alarm shield bit
0-
not shield alarm
1-shield alarm
-
0
0~1
1|2|3|4|5|6|
7|8|9|10
-
P0-69
Fan switch (
P0-69.0)
0- Turn on the fan when
the temperature greater
than 45
and turn off the
fan when less than 42
(hysteresis 3
)
1 - Turn on the fan after
enabling, turn off the fan
when not enabling
Large motor thermocouple
break alarm shield switch
(P0-69.1)
0-shield thermocouple
disconnection alarm
1-thermocouple
disconnection
-
1
0~1
1|2|3|4|5|6|
7|8|9|10
-
0
0~1
P0-74
Blocking alarm time
ms
0
0~5000
1|2|3|4|5|6|
7|8|9|10
5.8.1