8.2 Communication parameters
1. RS485 communication parameters
Parameter
Meaning
Default
setting
Range
Modify
Effective
P7-00
RS485 station number
1
0~100
Servo bb
At once
Parameter
Function
Unit
Default
setting
Suitable
mode
Modify
Effective
P7-01
Communication
setting
-
n.2206
All
Servo bb
At once
Setting
Default
setting
Range
n.xxx
Parity bit
0
0: no parity
1: odd
2: even
n.xxx
Stop bit
0
0: 2-bit
2: 1 bit
n.xx□□
Baud rate
06
00300
01600
021200
032400
044800
059600
0619200
0738400
0857600
09115200
0A192000
0B256000
0C288000
0D384000
0E512000
0F576000
10768000
111M
122M
133M
144M
155M
166M
Parameter
Meaning
Default
setting
Setting range
Modify
Effective
P7-02
RS485
communication
protocol
1
1-Modbus Rtu protocol
2-Xnet bus protocol
3-read Xnet bus torque
Servo bb
At once
2. RS232 communication parameter setting
Parameter
Meaning
Default
setting
Range
Modify
Effective
P7-10
RS232 station no.
1
0~100
Servo bb
At once